 DPF1000 SERIES
Dual output
* * * * * * * * 1000W front end EN61000-3-2 compliant 11 x 6.0 x 5.0 inch size Hot pluggable N+1 redundancy Full set of status signals EN55022, EN55011 conducted emissions level A UL, VDE and CSA safety approvals
[ 2 YEAR WARRANTY ]
The DPF1000 is a 1000W universal input AC/DC front end power supply in a fully enclosed hot pluggable case with built-in fan, handle, IEC input connector, on/off switch and DIN output signal connector. Providing dual 48V and 5V outputs with a full set of status signals. The DPF1000 is designed for use as a front end in medium power communication applications adopting distributed power architecture. The DPF1000 is fully compliant with EN61000-3-2. Standard features include current sharing and full protection against overvoltage, overload and short circuit. Remote or local system monitoring is possible via a full set of status signals that include fan fail, DC good, power fail, remote inhibit and current monitoring. The DPF1000, with full international safety approval and the CE mark, meets conducted emissions EN55022 level A. The DPF1000 can be used in conjunction with our complete range of 3 to 200W DC/DC converters to fully configure a distributed power system.
SPECIFICATION
OUTPUT SPECIFICATIONS Voltage set point Total regulation (Full load to no load) Rise time Transient response
All specifications are typical at nominal input, full load at 25C unless otherwise stated EMC CHARACTERISTICS -48V 0.1V @ 10A Radiated noise Conducted noise EN55022/11, FCC part 15 EN55022/11 FCC part 15 Harmonic current emm. EN61000-3-2 Electrical fast EN61000-4-4 transients/bursts Surge susceptibility EN61000-4-5 GENERAL SPECIFICATIONS Hold-up time Efficiency 110VAC, 60Hz 110VAC @ 1kW Input/output Input/chassis 20ms @ 1000W 77% min. 3000VAC 1500VAC 200kHz VDE0805, EN60950, IEC950 UL1950, BABT CSA C22.2 No. 950 4.3kg (9.5Ibs) MIL-HDBK-217F @ 25C full load 80,000 hours Level A Level A Level A Compliant Level 3 Level 3
Main output 5.0% Auxiliary output, 5V, 0.5A max. 5.0% At turn-on Main output 75% to 100% step at 0.1A/s Main output latching 1.0s, max. 5.0% max. dev., 1ms recovery 1.0V pk-pk, -57V to -60V min. 1200W Yes 10% sharing 0.1V/A droop 1/3L to FL
Ripple and noise (20MHz) Overvoltage protection Output power limit Short circuit protection Current sharing
Isolation voltage Switching frequency Approvals and standards Weight
INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Input surge Safety ground leakage current Input current Input fuse Power factor Notes
1 3 orthogonal axes, random vibration, 10 minute test per axis.
1000W 1200W
90 to 264VAC 108 to 264VAC 47Hz to 63Hz
MTBF
ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient, FL 0C to +50C Non-operating -40C to +70C 50C to 70C Derate linearly ambient to 50% at +70C Built-in fan Operating Operating Non-operating 5Hz to 500Hz MIL-STD-810E 5% to 85% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak 516.4 Part IV
25C cold start 300VAC 254.4VAC, 50Hz 90VAC, 1000W Replaceable 110VAC 220VAC
36A typ. 20ms 2.5mA
Cooling 14A rms max. 20A 0.99 0.98 Relative humidity Altitude Vibration (See Note 1) Shock
PAGE 1
DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES
|
1000W AC/DC
1000 Watt AC/DC PFC front-end for distributed power architectures
OUTPUT VOLTAGE -48V +5V MIN 0A 0A OUTPUT CURRENT RIPPLE MAX 21A 0.5A 1000mV 100mV Protection features
Overvoltage protection The unit will shutdown and latch off if the output voltage exceeds the OVP threshold. Input power recycling is necessary to restart the unit. Overcurrent and short circuit protection The unit is protected against an overload on its output in the range 25 to 30A, with automatic recovery on overload removal. Under short circuit conditions, the unit shuts down. Over temperature protection If the internal temperature of the unit exceeds a safe limit, the unit shuts down and will need power recycling to re-start. Input voltage sags A user supplied jumper inhibits operation of the unit in the 110V range. This limits the input current to a safe level when operating at 230V to prevent circuit breakers tripping under brown out. This programmable jumper can be accessible by removing the cover plate. Refer to view A on page 102.
TOTAL REGULATION 5.0%
MODEL NUMBER
DPF1000-9617PE 5.0%
Control and supervisory functions
Bias Supply H (Pin 1) Isolated 5V bias supply, maximum current 0.5A. Allows the system designer to power system control circuitry. PFC Fail L (Pin 2) A failure in the Power Factor Correction stage, i.e. loss of the 400V internal bus, is indicated by this open collector signal, asserted low. Bias Return L (Pin 3) Return path for the 5V bias supply. All signals are referenced to this return. Remote Inhibit H (Pin 4) The output is inhibited when this signal is tied high. IIL max. = 10mA. Voltage Trim (Pin 5) The output voltage can be adjusted up to -56V by connecting a 100k variable resistor between pin 5 and pin 14. Current Monitor (Pins 13, 14) Value: 0.1 x Iout. Tolerance: 10%. Range: 5 to 25A Power Good L (Pin 15) An open collector signal, asserted low. Threshold asserted: 44.5 to 46V, deasserted: 56.5 to 58V. See Figure 1. Fan Fail Detect L (Pin 16) An open collector signal, asserted low, indicates fan failure. See Figure 1. Power Fail Detect H (Pin 17) An open collector signal, asserted high, indicating AC line failure. The output voltage will stay within regulation 4ms after PFD is asserted.
Figure 1:
AC Input
48V Output
PFD Signal
PIN CONNECTIONS PIN NUMBER 1 2 3 4 5 6 to 12 13 14 15 16 17 18 to 24 SIGNAL 5V Bias PFC Fail 5V Bias Return/Signal Return Remote Inhibit H Voltage Trim -48V Return Current Monitor + Current Monitor Power Good L
Power Good Signal t1 t2
t1 varies with line and load t2 > = 4ms t1 + t2 > =20ms
Load sharing
The DPF1000-9617PE power supply provides load sharing capability for implementing parallel operation. An internal OR-ing diode is used in each output to provide N+1 redundancy. The power supplies will share the load current within 10% from full load down to1/3 of the rated current of each power supply. Method of current sharing of -48V output shall be via the "droop method", as illustrated in Figure 2 below:
Figure 2: Droop and Regulation Characteristics
Fan Fail Detect L Power Fail Detect H -48V
48V 46.9V 46.5V 50.4V (+5%) Setting Tolerance +0.10V (48.1V) -0.10V (47.9V) Output Voltage Total Output Tolerance Band
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-1090 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR50913/LR101320 Certificate No. PS/606473
45.6V (-5%) 10A Output Current 21A 25A (1000W) (1200W)
http://www.artesyn.com
PAGE 2
1000W AC/DC
|
DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES
1000 Watt AC/DC PFC front-end for distributed power architectures
3.00 (76.20)
VIEW A
SEE DETAIL 'B'
.98 (24.90)
VIEW B
J1
N L
0.25 (6.40)
J1
24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
N
L G
6.00 (152.40)
6.52 (165.60)
DETAIL 'B'
1.606 (40.79)
SEE DETAIL 'A'
2.149 (54.58)
5.00 (127.00) 11.00 (279.40)
24 23 22 21 20 19 18 17 16 15
12 11 10 9 8 7 6 5 4 3 2 1
VIEW A
VIEW B
14 13
J2 DETAIL 'A'
ALL DIMENSIONS IN INCHES (mm)
(J2) DC connector
Molex BMI receptacle 42474 part number 15-06-0240 or equivalent with Molex 5556 female crimp terminal part number 39-00-0182 or equivalent.
(J2) DC mating connector
Molex BMI plug 42475 part number 15-06-0246 or equivalent with Molex 5558 male crimp terminal part number 39-00-0220 or equivalent.
(J1) AC connector
Standard IEC connector.
(J1) AC mating connector
Standard IEC plug.
PAGE 3
DS_DPF1000_19980401.PDF
Data Sheet (c) Artesyn Technologies(R) 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 4


▲Up To Search▲   

 
Price & Availability of DFP1000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X